Beta-ray Particulate Concentration Monitor
Continuous particulate monitoring by beta-ray attenuation
Uses a low-energy C-14 beta source and measures attenuation through the filter to calculate airborne particulate mass concentration. Supports selectable inlets, sampling and measurement at the same filter position, dynamic heating and remote transmission.
Typical applicationsConstruction sites, Industrial facilities, Public spaces
- Measurement principle
- Beta-ray attenuation
- Measured parameters
- PM10 / PM2.5 / TSP, depending on the selected inlet
Specifications
| Measurement principle | Beta-ray attenuation |
|---|---|
| Measured parameters | PM10 / PM2.5 / TSP, depending on the selected inlet |
| Sample conditioning | DHS dynamic heating and temperature / humidity compensation |
| Data storage | Up to 365 days |
| Data transmission options | Wi-Fi / ZigBee / 3G / 4G / ADSL / optical fiber |
| Power-loss recovery | Data saved on power loss; sampling resumes when power returns |
Specifications are for reference only; the delivered configuration prevails.